Why lock ARDUN ignition timing at 26 degrees?
On the advice of Don Ferguson, who makes the heads: set it at 26 degrees advance and lock it there, so it starts at 26 and never goes above 26. Don thinks that is how they run best. Steve's distributor still has its mechanical advance, so he plans to lock it out before the dyno. The timing at the first start was about 10 degrees.
- Expert
- Steve Coppock
- Evidence
- expert attributed
- Component
- locked timing
- Applicable scope
- Ford Flathead V8 with ARDUN overhead valve heads, Steve Coppock's engine of about 289 cubic inches, on a home run stand before the dyno
Original BTG sourceFirst Fire-Up of a Legendary ARDUN Flathead Ford
Watch at 20:36.320 ↗