ignition · FF-0505

What ignition timing did the naturally aspirated ARDUN test use?

26 degrees, locked. There was no vacuum or mechanical advance in the distributor, so the timing was 26 degrees at start-up and 26 degrees at 6,000 RPM. Steve says that was Don Ferguson's recommendation, and he typically follows them.

Expert
Steve Coppock
Evidence
expert attributed
Component
ignition timing
Applicable scope
Steve Coppock's ARDUN overhead valve Ford Flathead V8 dyno engine
Original BTG sourceThe Flathead Flaw ARDUN Heads Actually Fixed (Dyno-Proven)
Watch at 26:04.400 ↗